Permanent New Laser Epilator IPL Hair Removal

$75.38
Color
Plug Type

Outstanding performance

1. 900000 flash times, LCD display
2.Support manual and automatic dual mode
3. Support 8-speed energy adjustment

Triple security protection

1.Built-in security sensor chip.
2. All-in-one machine, prevent side light and multiple insertion and removal damage
3. Multiple protection of the motherboard to ensure stable operation.

Humanized design concept

1. Multi-layer coated lens with wide band coverage and more efficacy.
(1-3 steps of hair removal to improve skin texture, 1-8 steps: hair removal)
2. Both size and appearance Mini is easier to carry, and it is easy to operate by holding the shape.
3. Large screen display parameters are easier to read.

USAGE STEPS

1) First plug in the power and turn on the machine; select the gear; for the first use, it is recommended to start slowly from the low gear to the appropriate gear.
2) Please put the laser head on the skin, after the energy indicator flashes, press the launch button to complete the operation; move to the next part and continue the operation.
3) After turning on the machine; short press the emission button for light emission operation, long press the emission button for automatic / manual light emission mode switching.

1. Safety Tips
To protect the skin, it s not suitable for the following customers:

*You have a known skin disorder;

*You have a skin disease such as allergic dermatitis, eczema etc;

*Who have photosensitization;

*If you are experiencing Menstruation, Pregnant or Lactation;

*If you have sunburn ;

*Black or sunburn skin (Please refer to the following specific color contrast card);

*Black or fuscescent nevus;

*Broken skin a scab or healed wound, cancer or hemangloma;

*Your eyes and any artificial aesthetic, prosthetic or plastic area.

2. Product Introduction
2.1 Packing list
 PL machine, Power adapter, Warranty card, Instruction manual.
2.2 Structutr Description


3.Technical Parameters
 

Lamp tube Xenon quartz tube
light source Intense Plused Light
Energy Frequency 1.2-3.9J/cm2
Focus size 4.2cm
Wavelength 470nm-1100nm
Lamp tube life 900000 times
Adaptor AC100-240V@12V DC 3A
Weight 210g
Size 168*112*78mm
Operating temperature range  5-30C
Operating humidity range Relative humidity 30%-60%

4. Functions Introduction
*Skin rejuvenation

*Hair removal

This product can be used for: excess hair such as lip hair armpit hair, limb body hair, forehead hair etc. Painless hair removal is suitable for black hair and dark-hair people, it is not suitable for white, gray or blonde(Refer to the following color contrast card)

Skin and hair color contrast card

skin color     hair color  white yellow medium brown light brown brown dark brown/black
white/grey × × × × × ×
red × × × × × ×
light gold × × × × × ×
light brown ×
brown ×
dark brown ×
black ×
 

5. Instructions For Use
5.1 Use a medical alcohol wipe to clean the glass window

5.2 contact machine with plug, "HR display on the screen

5.3 Press the"power button" for 3 second, it will start and enter into the working state The whole screen light up you can hear the system is running)

Note

1. You will see the"HR" light is on after starting up.

2. Then you should move the flash window to your skin, you will see the HR on the screen flickering, because there is a human body induction sensor built-in the flash window and the sensor will sense skin when you get close to it.

3. The "HR on the screen must be flickering, otherwise the device will not work. If you find that the "HR" on the screen not flickering, bring it closer to your skin until it does flicker.


5. 4 Click the "power button "to select the suitable intensity level,there are eight .The diagram below shows intensity level from low to high power, level I is the minimum power setting, level 8 is maximum power intensity. Any adjustment can be made in the sequence shown with a click of the power button.

5.5 Once the intensity level is set, move the flash window to the skin which can cover the flash window completely, you will see "HR "on the screen flickering and then click the flash button, the would will flash one time, after every flash.operation the "HR" remains on with out flicking to charge the power, after 1-3 seconds . It will return to indicating that it is ready for use again.
Note:

* For perfect results, it is suggested the process of hair removal is repeated 2-3 times and ensuring all the body parts should not be repeated and omitted.

*The device is not working correctly if the "HR" remains on without flickering, in this case, please follow the steps below;
1. Ensure the flash window 'is close enough to the skin;

2. If the HR on the screen is still on, please move to your skin for 3-5 seconds and check if it has return to a normal function ;

3. Please restart it if this operation failed;

4. If the above operation cannot solve it, please contact our customer service;

5. 6 press the power button for 3 seconds to shut down it;

5.7 When finished using, please clean the flash window using the suggested medical alcohol wet-wipe.

Note

After frequent use of the device there will be dew white spot insidethe lens, this will not affect the normal use and service life of the instrument.


6. Hair Management Process

6. 1 In test before us

It is strongly advised to check for adverse reaction by conducting a skin test 2 hours in advance of any hair removal procedure;

Test method

   On a small area of skin on the inside of the upper arm (the medial).
From a low energy to high energy apply 1-2 times at the same place. After 2 hours if you feel redness, burns, stabbing painor other symptoms consult a doctor before using again. On slight discomfort, use the product again on a lower intensity setting, owever if discomfort continues consult a doctor before further use.

6.2 Operating steps

* Clean the flash window, then shave the hair on your body and clean the residual hair ;

* Start the device, choose the best suitable intensity level to hair removal;

*After finish hair removal, you should cool the skin using Ice water or a cold damp towel;

* You can use a toner to help your skin retain moisture after hair removal;

* Suggestions about intensity level operations for all types  of skin and different parts of the body, please refer to the below comparison table;

*It is strongly suggested you do not use multiple times on the same part of skin. You should flash less than two times in succession only at one location.The operation frequency times should be reduced when using high energy intensity level.

intensity Level and skin color contrast table
     skin color       parts white yellow medium brown light brown brown dark brown/black
Armpit 6-8 leval  
3-4 times
6-8 leval  
-4 times
5-7 leval
 2-3 times
4-6 leval  
2-3 times
1-4 leval  
2-3 times
inapplicable
Arm 6-8 leval  
3-4 times
6-8 leval
3-4 times
5-7 leval  
2-3 times
1-4 leval  
2-3 times
1-4 leval  
2-3 times
inapplicable
Leg 6-8 leval 
3-4 times
6-8 leval  
3-4 times
5-7 leval  
2-3 times
1-4 leval  
2-3 times
1-4 leval  
2-3 times
inapplicable
Around Mouth 6-8 leval  
3-4 times
6-8 leval
3-4 times
4-6 leval  
2-3 times
1-4 leval
2-3 times
1-3 leval  
2-3 times
inapplicable
Face 6-8 leval  3-4 times 6-8 leval  3-4 times 4-6 leval  
2-3 times
1-4 leval  2-3 times 1-3 leval  2-3 times inapplicable

Note
*Using for 6-10 times as a hair removal cycle;

*Use one time every two weeks for up to six times;

*Use one time every four weeks when using 6-10 times;

*If you find new thin hair grow after use it, operate one time.
every 2-3 months at this place, and continue gaining satistying results;
*To gain the best results it is suggested that on areas of thick 
hair you use many times over a period of time;
*Use will vary from person to person, use less frequently 
when hair area grows by a small amount. about 30%.

7. Device Operation Notes

7. I Do not flash near or directly at the eyes when in use.
7.2 After operation, some skin redness is a normal you can cool the area with ice water or cold damp towel.

7. 3 Do not clean the flash window directly with spray alcohol.

7.4 Do not use in conjunction with other cosmetics such as 
water gel products.
7.5 Try not to eat light sensitive food during operation (such as 
spinach, cole, mustard, etc.)
7.6 For best results use the higher energy setting. (Warning 
only after following the previous instructions)
7. 7 The darker your skin any skin reaction may not be so 
apparent and the reaction may be delayed, in this case ensure the 2 hour waiting period is followed before Increasing the intensity setting.
7.8 Continue to look after you skin moisturizing and using Sun 
block in a normal way after using this product. 
7.9 Avoid UV light during use and always protection your skin when out in sun Also try to Avoid long exposure to computerradiation when working, protecting yourself with sun block or sunscreen.
7. 10 No not block the Air inlet and the cooling outlet so as not to 
affect the cooling of the device
7. 11 Hair stuck to the device may cause some blank spots but it 
does not affect the performance of the device and the normal use. 
7. 12 In the late period of life, the inner wall of the Light bulb will appear different degrees of black phenomenon, this is a result of the normal aging process of the tubes, Don t worry to continue to use as normal within the specified parameters.
7. 13 This product is not waterproof, avoid contact with water.

7. 14 Any faults, immediately unplug the device, If you find the factory for maintenance

7. 15 Do not store the device near Strong magnetic fields 
moisture dustor at high temperatures.
7. 16 Avoid damage and keep out of the reach and sight of children.
7. 17 Prohibit using it with other application which is not 
allowed.
7. 18 Prohibit other people opening this device except our 
authorized persons otherwise it may be danger electric shock.